Dynafuzz Stainless Fiber Media Element Upgrades

Hy-Pro Dynafuzz stainless fiber media element upgrades were developed to solve a steam turbine EHC system problem where glass media fibers were migrating and clogging servo screens.  Strong acids can develop in phosphate ester fluids and compromise media integrity in cases of high acid number and long term exposure.  Once OEM glass media pump discharge and servo pilot filter elements were upgraded to Hy-Pro Dynafuzz elements the problems with clogged servo screens went away.