Donaldson Hy-Pro TFR200 in-tank filter assemblies are ideal for contamination removal in medium to high flow rate applications on mobile equipment and hydraulic power units. Multiple inlet ports help simplify plumbing and reduce space and cost. The TFR200 utilizes patent protected filter elements to ensure performance and retain spare parts revenue.
Max Operating Flow: 200 gpm (757 lpm)
Max Operating Pressure: 150 psi (10 bar)
-20°F to 250°F
(-29°C to 121°C)
150 psi (10.3 bar) maximum
22 psi (1.5 bar)
45 psi (3.1 bar)
0-22 psi (0-1.5 bar), green to red
0-45 psi (0-3.1 bar), green to red
25 psid (1.7 bard) standard.
50 psid (3.4 bard) option, select Bypass Option “3” in Assembly Part Number Builder and add “-50” to the end of Replacement Element part number.
Nylon glass-filled
Our latest generation of DFE rated, low pressure drop, high performance glass media for all hydraulic & lubrication fluids. βx[C] ≥ 4000
G8 Dualglass high performance media combined with water removal scrim. βx[C] ≥ 4000
Stainless steel wire mesh media βx[C] ≥ 2 (βx ≥ 2)
Petroleum and mineral based fluids (standard). For polyol ester, phosphate ester, and other specified synthetic fluids use fluorocarbon seal option or contact factory.