TFR200 In-Tank Return Line Filter Assemblies

Donaldson Hy-Pro TFR200 in-tank filter assemblies are ideal for contamination removal in medium to high flow rate applications on mobile equipment and hydraulic power units. Multiple inlet ports help simplify plumbing and reduce space and cost. The TFR200 utilizes patent protected filter elements to ensure performance and retain spare parts revenue.

Max Operating Flow: 200 gpm (757 lpm)

Max Operating Pressure: 150 psi (10 bar)

Download Brochure

Operating Temperature

-20°F to 250°F

(-29°C to 121°C)

Operating Pressure

150 psi (10.3 bar) maximum

Pressure Switch Trigger

22 psi (1.5 bar)

45 psi (3.1 bar)

Visual Gauge

0-22 psi (0-1.5 bar), green to red

0-45 psi (0-3.1 bar), green to red

Integral Bypass Setting

25 psid (1.7 bard) standard.

50 psid (3.4 bard) option, select Bypass Option “3” in Assembly Part Number Builder and add “-50” to the end of Replacement Element part number.

Materials of Construction

Head & Cover

Cast Aluminum

Element End Caps

Nylon glass-filled

Media Description

L

Our latest generation of DFE rated, low pressure drop, high performance glass media for all hydraulic & lubrication fluids. βx[C] ≥ 4000

A

G8 Dualglass high performance media combined with water removal scrim. βx[C] ≥ 4000

W

Stainless steel wire mesh media βx[C] ≥ 2 (βx ≥ 2)

Fluid Compatibility

Petroleum and mineral based fluids (standard). For polyol ester, phosphate ester, and other specified synthetic fluids use fluorocarbon seal option or contact factory.

Replacement Elements
Replacement Elements
Max flow rates and ΔP factors assume υ = 150 SUS, 32 cSt. See filter assembly sizing guideline for viscosity conversion formula on page 22 for viscosity change.
ΔP Factors
K Factors
Filter Sizing Chart
TF4 filter sizing chart